Advanced search
1 file | 3.52 MB Add to list

Impact of deep learning denoising on kinetic modelling for low-dose dynamic PET : application to single- and dual-tracer imaging protocols

Author
Organization
Project
Abstract
Purpose Long-axial field-of-view PET scanners capture multi-organ tracer distribution with high sensitivity, enabling lower dose dynamic protocols and dual-tracer imaging for comprehensive disease characterization. However, reducing dose may compromise data quality and time-activity curve (TAC) fitting, leading to higher bias in kinetic parameters. Parametric imaging poses further challenges due to noise amplification in voxel-based modelling. We explore the potential of deep learning denoising (DL-DN) to improve quantification for low-dose dynamic PET. Methods Using 16 [18F]FDG PET studies from the PennPET Explorer, we trained a DL framework on 10-min images from late-phase uptake (static data) that were sub-sampled from 1/2 to 1/300 of the counts. This model was used to denoise early-to-late dynamic frame images. Its impact on quantification was evaluated using compartmental modelling and voxel-based graphical analysis for parametric imaging for single- and dual-tracer dynamic studies with [18F]FDG and [18F]FGln at original (injected) and reduced (sub-sampled) doses. Quantification differences were evaluated for the area under the curve of TACs, Ki for [18F]FDG and VT for [18F]FGln, and parametric images. Results DL-DN consistently improved image quality across all dynamic frames, systematically enhancing TAC consistency and reducing tissue-dependent bias and variability in Ki and VT down to 40 MBq doses. DL-DN preserved tumor heterogeneity in Logan VT images and delineation of high-flux regions in Patlak Ki maps. In a /[18F]FDG dual-tracer study, bias trends aligned with single-tracer results but showed reduced accuracy for [¹⁸F]FGln in breast lesions at very low doses (4 MBq). Conclusion This study demonstrates that applying DL-DN trained on static [18F]FDG PET images to dynamic [18F]FDG and [18F]FGln PET can permit significantly reduced doses, preserving accurate FDG Ki and FGln VT measurements, and enhancing parametric image quality. DL-DN shows promise for improving dynamic PET quantification at reduced doses, including novel dual-tracer studies.
Keywords
Deep learning denoising, Dynamic LAFOV PET, Low-dose imaging, Dual-tracer protocols, RECONSTRUCTION

Downloads

  • Muller - EJNMMI 2025 - DL DN Kinetic Modelling Single and Dual Tracer.pdf
    • full text (Published version)
    • |
    • open access
    • |
    • PDF
    • |
    • 3.52 MB

Citation

Please use this url to cite or link to this publication:

MLA
Muller, Florence Marie, et al. “Impact of Deep Learning Denoising on Kinetic Modelling for Low-Dose Dynamic PET : Application to Single- and Dual-Tracer Imaging Protocols.” EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, vol. 52, no. 9, 2025, pp. 3465–83, doi:10.1007/s00259-025-07182-6.
APA
Muller, F. M., Li, E. J., Daube-Witherspoon, M. E., Pantel, A. R., Wiers, C. E., Dubroff, J. G., … Karp, J. S. (2025). Impact of deep learning denoising on kinetic modelling for low-dose dynamic PET : application to single- and dual-tracer imaging protocols. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 52(9), 3465–3483. https://doi.org/10.1007/s00259-025-07182-6
Chicago author-date
Muller, Florence Marie, Elizabeth J. Li, Margaret E. Daube-Witherspoon, Austin R. Pantel, Corinde E. Wiers, Jacob G. Dubroff, Christian Vanhove, Stefaan Vandenberghe, and Joel S. Karp. 2025. “Impact of Deep Learning Denoising on Kinetic Modelling for Low-Dose Dynamic PET : Application to Single- and Dual-Tracer Imaging Protocols.” EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING 52 (9): 3465–83. https://doi.org/10.1007/s00259-025-07182-6.
Chicago author-date (all authors)
Muller, Florence Marie, Elizabeth J. Li, Margaret E. Daube-Witherspoon, Austin R. Pantel, Corinde E. Wiers, Jacob G. Dubroff, Christian Vanhove, Stefaan Vandenberghe, and Joel S. Karp. 2025. “Impact of Deep Learning Denoising on Kinetic Modelling for Low-Dose Dynamic PET : Application to Single- and Dual-Tracer Imaging Protocols.” EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING 52 (9): 3465–3483. doi:10.1007/s00259-025-07182-6.
Vancouver
1.
Muller FM, Li EJ, Daube-Witherspoon ME, Pantel AR, Wiers CE, Dubroff JG, et al. Impact of deep learning denoising on kinetic modelling for low-dose dynamic PET : application to single- and dual-tracer imaging protocols. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING. 2025;52(9):3465–83.
IEEE
[1]
F. M. Muller et al., “Impact of deep learning denoising on kinetic modelling for low-dose dynamic PET : application to single- and dual-tracer imaging protocols,” EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, vol. 52, no. 9, pp. 3465–3483, 2025.
@article{01JP5GVTV0ZJKDZ0ABM46XTSQN,
  abstract     = {{Purpose

Long-axial field-of-view PET scanners capture multi-organ tracer distribution with high sensitivity, enabling lower dose dynamic protocols and dual-tracer imaging for comprehensive disease characterization. However, reducing dose may compromise data quality and time-activity curve (TAC) fitting, leading to higher bias in kinetic parameters. Parametric imaging poses further challenges due to noise amplification in voxel-based modelling. We explore the potential of deep learning denoising (DL-DN) to improve quantification for low-dose dynamic PET.
Methods

Using 16 [18F]FDG PET studies from the PennPET Explorer, we trained a DL framework on 10-min images from late-phase uptake (static data) that were sub-sampled from 1/2 to 1/300 of the counts. This model was used to denoise early-to-late dynamic frame images. Its impact on quantification was evaluated using compartmental modelling and voxel-based graphical analysis for parametric imaging for single- and dual-tracer dynamic studies with [18F]FDG and [18F]FGln at original (injected) and reduced (sub-sampled) doses. Quantification differences were evaluated for the area under the curve of TACs, Ki for [18F]FDG and VT for [18F]FGln, and parametric images.
Results

DL-DN consistently improved image quality across all dynamic frames, systematically enhancing TAC consistency and reducing tissue-dependent bias and variability in Ki and VT down to 40 MBq doses. DL-DN preserved tumor heterogeneity in Logan VT images and delineation of high-flux regions in Patlak Ki maps. In a /[18F]FDG dual-tracer study, bias trends aligned with single-tracer results but showed reduced accuracy for [¹⁸F]FGln in breast lesions at very low doses (4 MBq).
Conclusion

This study demonstrates that applying DL-DN trained on static [18F]FDG PET images to dynamic [18F]FDG and [18F]FGln PET can permit significantly reduced doses, preserving accurate FDG Ki and FGln VT measurements, and enhancing parametric image quality. DL-DN shows promise for improving dynamic PET quantification at reduced doses, including novel dual-tracer studies.}},
  author       = {{Muller, Florence Marie and Li, Elizabeth J. and Daube-Witherspoon, Margaret E. and Pantel, Austin R. and Wiers, Corinde E. and Dubroff, Jacob G. and Vanhove, Christian and Vandenberghe, Stefaan and Karp, Joel S.}},
  issn         = {{1619-7070}},
  journal      = {{EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING}},
  keywords     = {{Deep learning denoising,Dynamic LAFOV PET,Low-dose imaging,Dual-tracer protocols,RECONSTRUCTION}},
  language     = {{eng}},
  number       = {{9}},
  pages        = {{3465--3483}},
  title        = {{Impact of deep learning denoising on kinetic modelling for low-dose dynamic PET : application to single- and dual-tracer imaging protocols}},
  url          = {{http://doi.org/10.1007/s00259-025-07182-6}},
  volume       = {{52}},
  year         = {{2025}},
}

Altmetric
View in Altmetric
Web of Science
Times cited: