Advanced search
1 file | 6.70 MB Add to list

Modelling lymph propulsion in a 3D model of murine collecting vessel with three lymphangions in series

(2023) ARTERY RESEARCH. 29(4). p.101-120
Author
Organization
Project
Abstract
The lymphatic system maintains tissue homeostasis by transporting the excess fluid from the interstitium and ultimately returning it to the venous circulation against an adverse pressure gradient and gravitational force. The spontaneous contractions of lymphangions, the building blocks of collecting vessels, and the secondary lymphatic valves play key roles in lymph propulsion. The aim of this study was to investigate lymph propulsion in a series of three contracting lymphangions in a 3D reconstructed model segmented from micro-CT scans of the collecting lymphatics in the hind limb of mice. Computational Fluid Dynamics and Fluid-Structure Interaction were used to study the behavior of flow within the collecting vessel, as well as the behavior and deformations of the vessel wall and the poroelastic interstitium. The secondary valves were modelled as porous membranes with closed or open states depending on their permeability. A sensitivity study revealed that the parameters having the most impact on the total volume of lymph propelled by active contraction of the lymphangions were the elastic modulus of the interstitium and the permeability of the secondary valves during the open states.
Keywords
Lymphatic system, Lymph propulsion, Computational fluid dynamics, Fluid-structure interaction, Poroelasticity, Micro-CT, Collecting vessels, Lymphangions, FLOW, SYSTEM, CONTRACTION, PUMP, PHYSIOLOGY

Downloads

  • s44200-023-00038-0.pdf
    • full text (Published version)
    • |
    • open access
    • |
    • PDF
    • |
    • 6.70 MB

Citation

Please use this url to cite or link to this publication:

MLA
Adeli Koudehi, Ghazal, et al. “Modelling Lymph Propulsion in a 3D Model of Murine Collecting Vessel with Three Lymphangions in Series.” ARTERY RESEARCH, vol. 29, no. 4, 2023, pp. 101–20, doi:10.1007/s44200-023-00038-0.
APA
Adeli Koudehi, G., Silvera Delgado, C. A., Van Impe, M., Cornillie, P., Casteleyn, C., Vanhove, C., … Segers, P. (2023). Modelling lymph propulsion in a 3D model of murine collecting vessel with three lymphangions in series. ARTERY RESEARCH, 29(4), 101–120. https://doi.org/10.1007/s44200-023-00038-0
Chicago author-date
Adeli Koudehi, Ghazal, Carlos Alejandro Silvera Delgado, Matthias Van Impe, Pieter Cornillie, Christophe Casteleyn, Christian Vanhove, Charlotte Debbaut, and Patrick Segers. 2023. “Modelling Lymph Propulsion in a 3D Model of Murine Collecting Vessel with Three Lymphangions in Series.” ARTERY RESEARCH 29 (4): 101–20. https://doi.org/10.1007/s44200-023-00038-0.
Chicago author-date (all authors)
Adeli Koudehi, Ghazal, Carlos Alejandro Silvera Delgado, Matthias Van Impe, Pieter Cornillie, Christophe Casteleyn, Christian Vanhove, Charlotte Debbaut, and Patrick Segers. 2023. “Modelling Lymph Propulsion in a 3D Model of Murine Collecting Vessel with Three Lymphangions in Series.” ARTERY RESEARCH 29 (4): 101–120. doi:10.1007/s44200-023-00038-0.
Vancouver
1.
Adeli Koudehi G, Silvera Delgado CA, Van Impe M, Cornillie P, Casteleyn C, Vanhove C, et al. Modelling lymph propulsion in a 3D model of murine collecting vessel with three lymphangions in series. ARTERY RESEARCH. 2023;29(4):101–20.
IEEE
[1]
G. Adeli Koudehi et al., “Modelling lymph propulsion in a 3D model of murine collecting vessel with three lymphangions in series,” ARTERY RESEARCH, vol. 29, no. 4, pp. 101–120, 2023.
@article{01HNX1FFPNAZRCZT4PMQP2KD7V,
  abstract     = {{The lymphatic system maintains tissue homeostasis by transporting the excess fluid from the interstitium and ultimately returning it to the venous circulation against an adverse pressure gradient and gravitational force. The spontaneous contractions of lymphangions, the building blocks of collecting vessels, and the secondary lymphatic valves play key roles in lymph propulsion. The aim of this study was to investigate lymph propulsion in a series of three contracting lymphangions in a 3D reconstructed model segmented from micro-CT scans of the collecting lymphatics in the hind limb of mice. Computational Fluid Dynamics and Fluid-Structure Interaction were used to study the behavior of flow within the collecting vessel, as well as the behavior and deformations of the vessel wall and the poroelastic interstitium. The secondary valves were modelled as porous membranes with closed or open states depending on their permeability. A sensitivity study revealed that the parameters having the most impact on the total volume of lymph propelled by active contraction of the lymphangions were the elastic modulus of the interstitium and the permeability of the secondary valves during the open states.}},
  author       = {{Adeli Koudehi, Ghazal and Silvera Delgado, Carlos Alejandro and Van Impe, Matthias and Cornillie, Pieter and Casteleyn, Christophe and Vanhove, Christian and Debbaut, Charlotte and Segers, Patrick}},
  issn         = {{1872-9312}},
  journal      = {{ARTERY RESEARCH}},
  keywords     = {{Lymphatic system,Lymph propulsion,Computational fluid dynamics,Fluid-structure interaction,Poroelasticity,Micro-CT,Collecting vessels,Lymphangions,FLOW,SYSTEM,CONTRACTION,PUMP,PHYSIOLOGY}},
  language     = {{eng}},
  number       = {{4}},
  pages        = {{101--120}},
  title        = {{Modelling lymph propulsion in a 3D model of murine collecting vessel with three lymphangions in series}},
  url          = {{http://doi.org/10.1007/s44200-023-00038-0}},
  volume       = {{29}},
  year         = {{2023}},
}

Altmetric
View in Altmetric
Web of Science
Times cited: