Progression of incomplete toward complete left bundle branch block : a clinical and electrocardiographic analysis
-
Failure to detect life‐threatening arrhythmias in ICDs using single‐chamber detection criteria
-
Haemodynamic management of patients with left ventricular assist devices using echocardiography : the essentials
-
Progression of incomplete to complete left bundle branch block
-
Gender differences in electro-mechanical characteristics of left bundle branch block : potential implications for selection and response of cardiac resynchronization therapy
-
Relation between electrical and mechanical dyssynchrony in patients with left bundle branch block : an electro- and vectorcardiographic study
-
Relation between electrical and mechanical dyssynchrony in patients with left bundle branch : an electrocardiographic and vectorcardiographic study
-
Accuracy of computer-calculated and manual QRS duration assessments : clinical implications to select candidates for cardiac resynchronization therapy
-
Biventricular paced QRS area predicts acute hemodynamic CRT response better than QRS duration or QRS amplitudes
-
The electrocardiographic characteristics of septal flash in patients with left bundle branch block
-
Shock-refractory ventricular fibrillation in a patient implanted with a left ventricular assist device
-
- Journal Article
- A2
- open access
Undetected ventricular fibrillation in a single-chamber implantable cardioverter-defibrillator : when the far-field channel sees more than the intraventricular channel
-
Electrocardiographic characteristics of the paced QRS complex according to different positions of the left ventricular lead in CRT patients
-
Diagnostic accuracy of a novel method for detection of acute transmural myocardial ischemia based upon a self-applicable 3-lead configuration
-
Different methods to measure QRS duration in CRT patients: impact on the predictive value of QRS duration parameters
-
Does septal flash on echocardiography defines true left bundle branch block?
-
Alternans of the ventricular electrogram in patients with an implanted cardioverter-defibrillator
-
Atrioventricular block precipitated by isoproterenol
-
Electrical atrial alternans recorded by cardiac rhythm devices during atrial flutter
-
Variability in interpretation of the electrocardiogram in young athletes: an unrecognized obstacle for electrocardiogram-based screening protocols
-
Alternans-induced ICD therapy
-
ICD sees what you do not see: how does it beat you?
-
Bipolar electrograms characteristics at the left atrial-pulmonary vein junction: toward a new algorithm for automated verification of pulmonary vein isolation
-
Mobitz type II second-degree atrioventricular block during dobutamine stress echocardiography: true or false?
(2014) ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES. 31(7). p.799-801 -
Novel algorithmic methods in mapping of atrial and ventricular tachycardia
-
Mapping and ablation of a narrow QRS tachycardia in a patient with ischemic cardiomyopathy
-
Juxtaposition of automatic mode switching and tachycardia-terminating algorithms in a dual-chamber implantable cardioverter-defibrillator
-
A 'shocking' case rectified
-
A review of the confirmation algorithm and related timing cycles of St. Jude ICDs
-
ECG-based screening of young athletes of a first division Belgian soccer team
-
Algorithmic EGM analysis: a first step towards an automated assessemnt of pulmonary vein isolation
-
Novel algorithmic methods to assess local activation time in atrial and ventricular tachycardia
-
Unusual cause of far-field atrial sensing by the ventricular lead of a dual chamber defibrillator: what is the mechanism?
-
Algorithmic detection of the beginning and end of bipolar electrograms: implications for novel methods to assess local activation time during atrial tachycardia
-
Device diagnosis of pacemaker-mediated tachycardia: true or false?
-
- Journal Article
- A1
- open access
Automatic mode switching of a dual chamber implantable cardioverter-defibrillator induced by a ventricular escape rhythm
-
Dissimilar ventricular rhythms : implications for ICD therapy
-
Implantable cardioverter-defibrillators: is there life after death?
-
Undersensing by an ICD due to alternans of the ventricular electrogram
-
The onset of bipolar electrograms: a novel algorithm to assess local activation time in atrial and ventricular tachycardia
-
The maximal negative slope in unipolar electrograms: a novel two-step algorithm to assess local activation time in atrial and ventricular tachycardia
-
Paroxysmal atrioventricular block precipitated by an atrial premature beat: what is the mechanism?
-
Phantom crosstalk
-
Limitations of the negative concordance pattern in the diagnosis of broad QRS tachycardia
-
Unusual cause of desynchronization in a cardiac resynchronization device
-
Rise in ICD shock impedance: lead fracture or death?
-
Functional atrial undersensing associated with switching to a tracking mode of pacing
-
P-wave locking in the postventricular atrial refractory period of cardiac resynchronization devices: management with the Biotronik system
-
Pacemaker repetitive nonreentrant ventriculoatrial synchrony: why did automatic mode switching occur?
-
Using devices with a variable postventricular atrial refractory period for cardiac resynchronization