prof. ir. Tom Claessens
- Work address
-
Valentin Vaerwyckweg 1, Schoonmeersen - gebouw D
9000 Gent - Tom.Claessens@UGent.be
- ORCID iD
-
https://orcid.org/0000-0002-3182-6820
Show
Sort by
-
Single calibration multiplane stereo-PIV : the effect of mitral valve orientation on three-dimensional flow in a left ventricle model
-
Analyzing virtual physics simulations with tracker
-
- conference
- C3
- open access
Experimental Investigation of 3D Left Ventricular Flow Using a Novel Multiplane Scanning Stereo PIV Setup
(2017) p.1-2 -
- conference
- C3
- open access
A Novel Multiplane Scanning Stereo PIV Setup to Investigate Left Ventricular Flow
(2017) p.1-1 -
- conference
- C3
- open access
A Novel Multiplane Scanning Stereo PIV Setup to Investigate Left Ventricular Flow
(2016) -
- conference
- C3
- open access
Multiplane Scanning Stereo PIV for Biofluid Applications
(2015) -
3D-printing of (Recycled) Polyolefins
-
Influence of valve size, orientation and downstream geometry of an aortic BMHV on leaflet motion and clinically used valve performance parameters
-
- journalArticle
- A1
- open access
The use of rapid prototyped implants to simulate knee joint abnormalities for in vitro testing: a validation study with replica implants of the native trochlea
-
Validation of a numerical FSI simulation of an aortic BMHV by in vitro PIV experiments
-
Effective arterial elastance is insensitive to pulsatile arterial load
-
Numerical evaluation and experimental validation of pressure drops across a patient-specific model of vascular access for hemodialysis
-
Semi-automated 3D analysis reveals new morphological differences between normal and trochleodysplatic knees
(2013) -
Manufacturing of patient-specific optically accessible airway models by fused deposition modeling
-
- journalArticle
- A1
- open access
Early and late systolic wall stress differentially relate to myocardial contraction and relaxation in middle-aged adults: the Asklepios study
-
- journalArticle
- A1
- open access
A fast strong coupling algorithm for the partitioned fluid–structure interaction simulation of BMHVs
-
Computational models for wall shear stress estimation in scaffolds: a comparative study of two complete geometries
-
Assessment of variables affecting late left ventricular flow propagation velocity
-
Analysis of the clinical performance of an aortic BMHV by numerical simulation
-
- journalArticle
- A1
- open access
The upstream boundary condition influences the leaflet opening dynamics in the numerical FSI simulation of an aortic BMHV
-
- journalArticle
- A1
- open access
Application of a strong FSI coupling scheme for the numerical simulation of bileaflet mechanical heart valve dynamics: study of wall shear stress on the valve leaflets
-
Assessment of variables affecting late left ventricular flow propagation velocity (Vpa): an echocardiographic study
-
Anatomically realistic geometrical boundary conditions for the numerical FSI simulation of an aortic BMHV
-
- bookChapter
- open access
State-of-the-art methods for the numerical simulation of aortic BMHVs
-
Histogram analysis: a novel method to detect and differentiate fractionated electrograms during atrial fibrillation
-
A strong FSI coupling scheme for simulating BMHV dynamics: study of wall shear stress on the valve leaflets
-
Experimental and numerical flow vizualization in patient specific pre operative human airway geometry
-
The influence of the upstream boundary condition in the numerical simulation of the opening of an aortic BMHV
-
Anatomical and functional changes in the upper airways of sleep apnea patients due to mandibular repositioning: a large scale study
-
Cardiac mechanics
-
Mitral valve leakage quantification by means of experimental and numerical flow modeling
-
Noninvasive assessment of diastolic intraventricular pressure gradients in a large general population (the Asklepios study)
-
- conference
- P1
- open access
Evaluation of a new implicit coupling algorithm for the partitioned fluid-structure interaction simulation of bileaflet mechanical heart valves
-
Numerical simulation of a 3D bileaflet mechanical heart valve: FSI coupling algorithm
-
Flow analysis in patient specific lower airways using PIV
-
- conference
- C3
- open access
Computational fluid dynamics as a predictive technique for the patient-specific success of mandibular repositioning appliances
-
Left ventricular mass: allometric scaling, normative values, effect of obesity, and prognostic performance
-
Rapid prototyping for fabricating digital PIV compatible subject-specific models of the lower human airways
-
Towards cost-efficient RPM technology for patient specific PIV models
-
- conference
- C1
- open access
In Vitro Flow Modelling for Mitral Valve Leakage Quantification
(2009) -
In vitro, in vivo and numerical assessment of the working principle of the truCCOMS™ continuous cardiac output catheter system
-
Relationship Between Ventricular Afterload and Early Diastolic Ventricular Relaxation: The Asklepios Study
-
- conference
- C3
- open access
Experimental study of the flow field in patient specific lower airways
-
- conference
- C3
- open access
Functional imaging on patient-specific lower airways using Computational Fluid Dynamics
-
Design of an artificial left ventricular muscle: an innovative way to actuate blood pumps?
-
An innovative design of a blood pump actuator device using an artificial left ventricular muscle
-
Innovative design of an artificial left ventricular model incorporating longitudinal and radial shortening and ventricular torsion
-
Experimental and numerical flow modeling towards refinement of three-dimensional echocardiography for heart valve leakage quantification
-
Linking heart development to flow induced shear stresses
-
Relation between arterial load and left ventricular relaxation in a large population sample of healthy, middle-aged subjects.